components and metrics. You can also monitor real-time data, plot trend values for all the charts, and plot
forecast lines for critical metrics to predict behavior within a specified time frame.
Continuous Access screen details
Screen elements Description
Filters
Arrays Displays all the arrays that PA monitors.
Pair Status Displays the records which have the CA Pair Status as Ok,
Warning, Critical or Unknown.
CA Link Status Displays the CA link of all statuses by default. The status
displays as critical if the CA Link is down.
Master pane details
Pair Status Current replication link status of the P-VOL or S-VOL on the
selected array. The replication link status shown is corresponding
to the continuous access transactions happening on the selected
array, and can be one of the following:
• SMPL
• COPY
• PAIRED
• Pair Suspendx
• Pair Suspend Error
• Pair DUB
• Reverse Copy
• Pair SideFile 30% over
• Pair SideFile over Suspend
• SVOL Swap ready Suspend
• Unknown
Primary DKC Serial number of the primary disk array (primary data center).
PVOL LDEV configured as P-VOL on the primary data center. Displays
the LDEV number in cu:LDEV format.
PVOL Host Port Host port assigned for the P-VOL.
Secondary DKC Serial number of the secondary array.
Table Continued
246 Continuous Access screen details