Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd
―124― HD30 Series Inverters User Manual
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F00.17
Operation direction
selection
0: The same as run
command
1: Opposite to run command
0 1 ×
F00.18 Anti-reverse operation
0: Reverse operation is
permitted
1: Reverse operation is
prohibitted
0 1 ×
F00.19
Dead time of direction
switch
0.0-3600.0s 0.0s 0.1s ×
Group F01 Protection of Parameters ( refer to pages 57
59)
F01.00 User’s password 00000-65535 0 1 ○
F01.01 Menu mode selection
0: Full menu mode
1: Checking menu mode
(Only different from factory
setting parameters can be
displayed)
0 1 ○
F01.02
Function code
parameter initialization
0: No operation
1: Restore to factory settings
2: Download the display
panel EEPROM parameter 1
to the current function code
settings
3: Download the display
panel EEPROM parameter 2
to the current function code
settings
4: Clear fault information
0 1 ×
F01.03
Display panel
EEPROM parameter
initialization
0: No operation
1: Upload the current
function code settings to the
display panel EEPROM
parameter 1
2: Upload the current
function code settings to the
display panel EEPROM
parameter 2
0 1 ○
Group F02 Run/Stop Control Parameters (refer to pages 59
62)
F02.00 Start mode selection
0: From the DWELL
frequency to start
1: Brake first and then start
from DWELL frequency
2: Start after speed tracking.
If the result of speed tracking
is smaller than F02.02, it will
start from the starting
DWELL frequency
0 1 ×
F02.01 Starting delay time 0.00-10.00s 0.00s 0.01s ×