EasyManua.ls Logo

HPRT TP809

HPRT TP809
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TP809 Programming Manual
<Function 167> GS ( k pL pH cn fn n (cn = 49, fn = 67)
[Function]
QR Code: Set the size of module
[Format]
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 31 43 n
Decimal
29 40 107 3 0 49 67 n
[Range]
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 49
fn = 67
1 ≤ n ≤ 16
[Default]
n = 3
[Description]
Set the size of the module for QR Code to n dots
<Function 169> GS ( k pL pH cn fn n (cn = 49, fn = 69)
[Function]
QR Code: Select the error correction level
[Format]
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 31 45 n
Decimal
29 40 107 3 0 49 69 n
[Range]
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 49
fn = 69
48 ≤ n ≤ 51
[Default]
n = 48
[Description]
• Selects the error correction level for QR Code.
n
Function
Reference: Approx. figure of recovery
48
Select error correction level L
7 %
49
Select error correction level M 1
15 %
50
Select error correction level Q 2
25 %
51
Select error correction level H 3
30 %