- 60 -
„I
Start
If I
Target
is acvated, I
start
appears. This value denes the point at which the
stroke measurement for the seng step is to be started.
„I
limit
I
limit
describes the max. current that the tool can reach in this step. When
this value is reached, the tool stops and displays an NOK error message.
DANGER

Incorrect parametrisation can lead to injuries or damage
Settings may only be made by experienced users.
me
„T
target
T
Target
describes the me for which the tool should run in this step. When
this value is reached, the tool changes to the next step.
„T
limit
T
limit
describes the max. me that the tool can run in this step. When
this value is reached, the tool stops and displays an NOK error message.
switch
„pressure trigger If the Pressure trigger funcon is acvated in the step, the pressure
trigger must be acvated. Default: deacvated
„nal switch“ The limit switch funcon must always be acvated so that the tool
cannot move onto the block.
evaluaon
„force The force value determines the force range in which the operang point
has to be in and evaluates the riveng process with OK or NOK.
„stroke“ The stroke value determines in which stroke range the operang point
has to be in and evaluates the riveng process with OK or NOK.
„current The current value determines the current range in which the operang
point has to be in and evaluates the riveng process with OK or NOK.
„me“ The me denes the me range in which the operang point has to be
in and evaluates the riveng process with OK or NOK.