- 60 -
„I
Start
“ If I
Target
is acvated, I
start
appears. This value denes the point at which the
stroke measurement for the seng step is to be started.
„I
limit
“ I
limit
describes the max. current that the tool can reach in this step. When
this value is reached, the tool stops and displays an NOK error message.
DANGER
Incorrect parametrisation can lead to injuries or damage
• Settings may only be made by experienced users.
me
„T
target
“ T
Target
describes the me for which the tool should run in this step. When
this value is reached, the tool changes to the next step.
„T
limit
“ T
limit
describes the max. me that the tool can run in this step. When
this value is reached, the tool stops and displays an NOK error message.
switch
„pressure trigger“ If the Pressure trigger funcon is acvated in the step, the pressure
trigger must be acvated. Default: deacvated
„nal switch“ The limit switch funcon must always be acvated so that the tool
cannot move onto the block.
evaluaon
„force“ The force value determines the force range in which the operang point
has to be in and evaluates the riveng process with OK or NOK.
„stroke“ The stroke value determines in which stroke range the operang point
has to be in and evaluates the riveng process with OK or NOK.
„current“ The current value determines the current range in which the operang
point has to be in and evaluates the riveng process with OK or NOK.
„me“ The me denes the me range in which the operang point has to be
in and evaluates the riveng process with OK or NOK.