EN - 11
5.2.2. Auto Power OFF
Move the cursor to Auto power off by means of the arrow
keys (,) and confirm with ENTER. Subsequently, the
displays shows the setting screen which allows
enabling/disabling the auto power off of the instrument after a
period of 5 minutes inactivity.
Select the desired option by means of the arrow keys (,).
To store settings, press the ENTER key, to exit the changes
made, press the ESC key.
OFF
ON 5 min
OFF

VAL
5.2.3. Nominal voltage
Move the cursor to Nominal V by means of the arrow keys
(,) and confirm with ENTER. Subsequently, the displays
shows the screen which allows setting the value of the
voltage to be used for calculating the prospective short-circuit
current.
Select the desired option by means of the arrow keys (,).
To store settings, press the ENTER key, to exit the changes
made, press the ESC key.
VNOM
Vp-n=230V Vp-p=400V
Vp-n=240V Vp-p=415V

VAL
5.2.4. Frequency
Move the cursor to Frequency by means of the arrow keys
(,) and confirm with ENTER. Subsequently, the displays
shows the screen which allows setting the value of the mains
frequency.
Select the desired option by means of the arrow keys (,).
To store settings, press the ENTER key, to exit the changes
made, press the ESC key.
FREQ
50 Hz
60 Hz

VAL
5.2.5. System
Move the cursor to System by means of the arrow keys
(,) and confirm with ENTER. Subsequently, the display
shows the screen which allows selecting the type of electric
power supply system. The “GO STOP” item allows to
eventually disable the check of voltage on PE conductor by
pressing the GO/STOP key
Select the desired option by means of the arrow keys (,).
To store settings, press the ENTER key, to exit the changes
made, press the ESC key.
SYS
TT/TN system
IT system
GO STOP

VAL
5.3. MEM
By selecting MEM with the cursor and confirming selection with ENTER, the memory
management is accessed (§ 8)
5.4. RS232
Select the item RS232 to enable the management of data transfer to PC (see § 9)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HT 400 Series and is the answer not in the manual?

HT 400 Series Specifications

General IconGeneral
TypeDigital Multimeter
Diode TestYes
Auto RangingYes
Data HoldYes
Operating Temperature0°C to 40°C
DC Current Range400μA to 10A
AC Current Range400μA to 10A
Resistance Range400Ω to 40MΩ
Continuity TestYes
DisplayLCD, 4000 counts
Measurement RangeAs per individual functions

Related product manuals