Indicator State Description
Management module health
indicator
Blinking green: The module is operating properly.
Red: A health event has been reported.
Off: There is no power supply, or the module is faulty.
Management module
active/standby status
indicator
Green: The management module serves as an active one.
Off: The management module serves as a standby one.
Fan module indicator
l Blinking green (at 0.5 Hz): The fan module is properly
communicating with the management module, and no
alarm is generated from the fan module.
l Blinking green (at 4 Hz): The fan module is improperly
communicating with the management module, and no
alarm is generated from the fan module.
Blinking red (at 0.5 Hz): An alarm has been generated on the
fan module.
Off: There is no power supply.
Serial port activity
indicator
The indicator is reserved.
GE electrical port activity
indicator
Orange: Data is being transmitted over the port.
Off: No data is being transmitted over the port.
GE electrical port link
status indicator
Green: The port link status is up.
Off: The port link status is not up.
PSU indicator
l Steady green: The PSU is working properly.
l Blinking green (at 0.5 Hz): There is power supply but the
PSU is not enabled.
l Blinking green (at 2 Hz): The PSU is in hibernation
mode.
Amber: There is no power output due to faults such as input
overvoltage, fault module failure, output overcurrent, short
circuits, or output overvoltage or undervoltage.
Off: There is no power supply, or the module is faulty.
Figure 2-13 shows the ports on the rear panel of a server.