Checking the Power Jumpers on the Board
Check the power jumper settings and modify the settings as required. By default, the power jumpers are capped.
Position of the jumpers of the N3GSCC (layout 1)
To set the input voltage of the
equipment
When the jumpers are not capped, the equipment is
supplied with the 60 V power.
When the jumpers are capped, the equipment is
supplied with the 48 V power.
Position of the jumpers of the N3GSCC (layout 2)
To set the input voltage of the
equipment
NOTE
NOTE
NOTE
When the jumpers are not capped, the equipment is
supplied with the 60 V power.
When the jumpers are capped, the equipment is
supplied with the 48 V power.