The power cables of the RPS1800 and switch can be connected to the same or different
external power supply systems, as shown in Figure 9-5 and Figure 9-6, according to power
reliability requirements.
Figure 9-5 Connecting the RPS1800 and switch to the same external power supply system
~100-240V;50/60Hz;7A
+12V;10A
-53.5V;15A
~100-240V;50/60Hz;16 A
OUTPUT1 -53.5V/15A;12V/12.5A OUTPUT2 -53.5V/15A;12V/12.5A OUTPUT3 -53.5V/15A;12V/12.5A OUTPUT4 -53.5V/15A;12V/12.5A OUTPUT5 -53.5V/15A;12V/12.5A OUTPUT6 -53.5V/15A;12V/12.5A
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6
TOP
Figure 9-6 Connecting the RPS1800 and switch to different external power supply systems
~100-240V;50/60Hz;7A
+12V;10A
-53.5V;15A
~100-240V;50/60Hz;16 A
OUTPUT1 -53.5V/15A;12V/12.5A OUTPUT2 -53.5V/15A;12V/12.5A OUTPUT3 -53.5V/15A;12V/12.5A OUTPUT4 -53.5V/15A;12V/12.5A OUTPUT5 -53.5V/15A;12V/12.5A OUTPUT6 -53.5V/15A;12V/12.5A
TOP
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6
----End
S2700&S3700&S5700&S6700 Switch
Hardware Installation and Maintenance Guide
9 (Optional) Installing an RPS1800
Issue 13 (2017-11-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
73