3.2 Measuring the Wheel with Inner and Outer Auto Dataset
®
Arms
Auto Dataset
®
is a faster and more accurate method to take rim measurements than
traditional manual wheel data entry methods. Auto Dataset
®
is used to input rim
distance, rim width, and weight plane location automatically. The Dataset
®
arms of
the DSP9200 are positioned at the weight plane and data is entered by depressing
the foot pedal.
Measuring Dimensions for Clip-On Weights:
Lift or pull the inner Dataset
®
arm away from the weight tray to trigger a new left
plane reading. A beep will occur and the green LED left rim lip “weight” will blink to
prompt for the input of the left plane weight. When the arm is steady, step on the foot
pedal, a confirmation beep occurs, the inner distance and rim diameter readouts are
updated, and the prompt stops blinking.
Lift or push the outer Dataset
®
arm toward the weight tray to trigger a new right plane
reading. A beep will occur and the green LED right rim lip “weight” will blink to prompt
for the input of the right plane weight. When the arm is steady, step on the foot pedal,
a confirmation beep occurs, the wheel width readout updates and the prompt stops
blinking.
TIPS:
1. Both Dataset
®
arms may be used simultaneously.
2. If the balancer determines that the weight planes are too close together, the
weight digits will be turned off and the distance and the width digits will start
blinking. Re-enter the planes to correct this condition.
3. If the Dataset
®
arm is not steady when the foot pedal is depressed, there will be a
long error beep.
4. If the Dataset
®
arm is returned to the storage position before a reading is taken,
the trigger is canceled and the prompt stops blinking.
5. After taking a reading, the Dataset
®
arm must be returned to the storage position
to trigger a new reading.
6. If STATIC mode is in effect, distance readouts will not be updated. Distance
readouts are not used in STATIC mode.
NOTE: The wheel diameter input by the inner auto Dataset
®
arm
might be slightly different from the known nominal wheel (tire
bead seat) diameter. The auto Dataset
®
arm measures the
actual weight circle instead for the rim lip configuration of the
wheel. A more accurate wheel balance will result if the
reading is not manually (knob) adjusted to the nominal wheel
diameter.