The right weight digits display the software version number.
This manual provides operating instructions for the DSP9200 wheel balancer with
software revision 1.0 and higher.
5.5 Calibration Procedures
“Calibration” can be selected by pressing the “Setup/Cal” button.
Store the calibration weight, 65-72-2, in the threaded hole on the back of the control
panel support.
Dataset
®
arm calibration requires the optional calibration tool, 221-602-1.
Quick Cal Check
Begin with balancer “OFF,” then turn “ON.”
Attach cal weight to either side of one of the two holes in the hub faceplate.
Lower hood and press the
“Start” button to spin. Display shows “CAL RDY” or
“CAL ERR.”
NOTE: If “CAL ERR” is displayed, the balancer needs to be
recalibrated.
Whichever side the cal weight was installed, a plane weight position indicator will be
displayed.
Check angle accuracy by verifying that the cal weight stops at TDC (12 o’clock
position). If cal weight is in a position other than TDC, perform calibration procedure.
Press the
“Next” button to show weights.
The Quick Cal™ Check is complete.
58
5. Maintenance and Calibration DSP9200 Series Balancer Operation Instructions