Outer Dataset
®
Arm (Calibration Tool, 221-672-1, Required)
With the hood in the raised position, verify that the outer arm is in the “home” position
and that the arm and hood are not moving. Tap the foot pedal once or press “Enter.”
Place the calibration tool on the hub using the hub mounting slot as shown.
Place the outer Dataset
®
arm ball in hole position “1.” Tap the foot pedal once or
press “Enter.”
Place the outer Dataset
®
arm ball in hole position “2.” Tap the foot pedal once or
press “Enter.”
Place the outer Dataset
®
arm ball in hole position “3.” Tap the foot pedal once or
press “Enter.”
Dataset
®
arm calibration is complete. “RDY” is displayed near the inner arm graphic
to indicate that the inner Dataset
®
calibration passed. “RDY --]” is displayed on the
weight digits to indicate that the outer Dataset
®
calibration passed.