3.5 Standard Balancing Procedure (Clip-on Weights)
Mount wheel.
Press the
“Static/Dynamic” button to select DYNAMIC .
Press the
“Standard/ALU” button until both clip-on weights are blinking.
Measure and enter the distance to the wheel inner rim lip and rim diameter as shown
below:
“P195/75R-15”
Measurement can be input automatically, if the DSP9200 is equipped with the
optional auto inner and/or outer Dataset
®
arms.
DSP9200 Series Balancer Operation Instructions 3. Balancing a Wheel