OPERATION
5
4-18 HPR130 Manual Gas Instruction Manual
Stainless steel
H35 Plasma / N
2
Shield
130 A Cutting
220198220173 220307220304 220179220197
Note: This process produces a smoother, shinier cut edge with less dross, and the cut edges are less
perpendicular than the 130 A, N
2
/N
2
process
Flow rates – lpm/scfh
H35
N
2
Preflow 0 / 0 76 / 160
Cutflow 26 / 54 68 / 144
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts mm mm/m mm factor % seconds
H35
N
2
20 40 70
60
10
154
4.5
980
7.7 170
0.3
45
12
158 820 0.5
30
15
162 580 0.8
20
165 360 1.3
20
25
172 260 Edge start
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts in ipm in factor % seconds
H35
N
2
20 40 70
60
3/8
154
0.180
40
0.310 170
0.3
45
1/2
158 30 0.5
30
5/8
162 20 0.8
3/4
165 15 1.3
20
1
172 10 Edge start
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm in mm/min ipm Volts
N
2
N
2
10 10 10 10
18
2.5 0.100 6350 250 130
Marking