OPERATION
HPR130 Manual Gas Instruction Manual 4-19
6
Aluminum
Air Plasma / Air Shield
45 A Cutting
220202220173 220308220176 220180220201
Flow rates – lpm/scfh
Air
Preflow 45 / 95
Cutflow 78 / 165
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts mm mm/m mm factor % seconds
Air Air 35 25 55
60
1.2
130
2.5
4750
3.8
150
0.2
1.5
115 4160
2
113 3865
2.5
110 3675
3
107 2850
40
4
102 1.8 2660 2.7 0.3
6
117 3.0 1695 4.5 0.6
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts in ipm in factor % seconds
Air Air 35 25 55
60
.040
130
0.100
220
0.150
150
0.2
.051
115 170
.064
113 160
.102
110 140
40
.125
102 0.070 110 0.110 0.3
3/16
114
0.120
90
0.180
0.4
1/4
117 60 0.6
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm in mm/min ipm Volts
N
2
N
2
10 10 10 10
15
2.5 0.100 6350 250 85
Marking