Acoustics
Slicestor
®
2584 produces an operating sound power of < LWAd 8.2 Bels (re 1pW) at an ambient
temperature of 73°F (23°C).
AC power cords
If supplying your own power cord, you must meet a number of specifications.
Table 20. Power cord specifications
Country Cord type Plug (AC source) Socket (PSU socket) Comments
USA SJT or SVT, 12 AWG
minimum, 3
conductor
IEC 320 C20, 250V,
20A or a suitable plug
rated 250V, 20A
IEC 320 C19, 250V,
20A
Must be NRTL
LISTED (National
Recognized Test
Laboratory, such as
UL)
Europe & Others Harmonized,
H05-VVF-3G2.5
IEC 320 C20, 250V,
16A or a suitable plug
rated 250V, 16A
IEC 320 C19, 250V,
16A
Important: The plug and the complete power cord assembly must meet the standards appropriate to the
country, and must have safety approvals acceptable in that country.
SMM Phase
POST Codes – SMM Phase
Table 21. POST Codes – SMM Phase
Description Value
SMM_IDENTIFY_FLASH_DEVICE 0xA0
SMM_SMM_PLATFORM_INIT 0xA2
SMM_ACPI_ENABLE_START 0xA6
SMM_ACPI_ENABLE_END 0xA7
SMM_S1_SLEEP_CALLBACK 0xA1
SMM_S3_SLEEP_CALLBACK 0xA3
SMM_S4_SLEEP_CALLBACK 0xA4
SMM_S5_SLEEP_CALLBACK 0xA5
SMM_ACPI_DISABLE_START 0xA8
SMM_ACPI_DISABLE_END 0xA9
56 Slicestor
®
2584 Appliance Manual