a) Insert the CMA body connector (E) into the outer rail connector (D).
b) Insert the inner CMA connector (A) into the inner rail connector (B).
c) Insert the outer CMA connector (C) into the outer rail connector (D).
3. Install the CMA in the top canister:
Figure 34. Installing the CMA in the top canister
a) Insert the inner CMA connector (A) into the inner rail connector (B).
b) Insert the outer CMA connector (C) into the outer rail connector (D).
c) Insert the CMA body connector (E) into the outer rail connector (D).
4. Connect the cables to the appropriate ports on the server canister operator panels and the jacks for
the power modules.
CAUTION:
Do not connect the power cords to a power module yet.
5. Starting with the thickest gauge cable rst, run each cable through the loops on the CMA.
6. Test the CMA to ensure smooth operation. Ensure that the cables do not have pinching or bindings.
Note: When you pull an enclosure from the rack, the rails lock in the service position. To release the
rails from the service position, press the release tab on each inner member rail and simultaneously
push the enclosure into the rack.
Chapter 4. Installing
51