109Troubleshooting
No action required.
P
A1 SELECTED
1. Attach status message.
No action required.
P
A2 SELECTED
1. Attach status message.
No action required.
P05 DIAGNOSTIC TEST PASSED
1. Non-error status message: the printer passed its memory and hardware
initialization tests.
No action required.
P17 SECURITY VIOLA
TION
1. Security code of the PAL on the CMX controller board does not match the code
of the firmware on the CMX controller board. Remove the paper guide assembly
or pedestal top cover. Check that the security PAL is correctly installed. (See
Figure 34, page 226.)
Install correct PAL for the customer’s emulations with the notched end
facing toward the flash and DRAM SIMM sockets.
2. Run a print test.
If the message appears, replace the CMX controller board. Record the
message and return it with the defective board.
P60 ERROR:
DRAM AT ADDRESS <hex>
1. The printer found a defective memory location.
Replace the DRAM. (See Figure 34, page 226.)
2. Power on the printer.
If the message appears, replace the CMX controller board. Record the
message and return it with the defective board.