Replacement Procedures and Illustrated Parts List
Magnetic Pick-up (MPU) Assembly
Removal
1. Prepare the printer for maintenance (page 194).
2. Remove the shuttle cover (page 209).
3. Disconnect the shuttle cable assembly connector (page 275, Figure 45).
4. Disconnect the magnetic pick-up (MPU) cable connector (page 279,
Figure 47).
5. Loosen the 7/64 inch hex MPU clamp screw (page 279, Figure 47).
6. Unscrew the MPU assembly from the MPU bracket.
Installation
1. Install the MPU assembly by screwing it into the MPU bracket (page 279,
Figure 47).
2. Using a feeler gauge, adjust the gap between the MPU assembly and the
flywheel to 0.010
± .001 inch (0.254 ± 0.025 mm). Torque the MPU
clamp screw to 19 ± 1 inch-pounds (2.15 ± 0.11 Nm).
3. Check the gap between the MPU assembly and the flywheel with a feeler
gauge:
a. If the gap is 0.010
± .001 inch (0.254 ± 0.025 mm), go to step 4.
b. If the gap is not 0.010
± 0.001 inch (0.254 ± 0.025 mm), loosen the
MPU clamp screw and go back to step 2.
ATTENTION
Make sure the MPU cable is below the extension spring and does not
touch the spring after the cable is connected.
4. Connect the magnetic pick-up (MPU) cable connector.
5. Connect the shuttle cable assembly connector (page 279, Figure 47).
6. Install the shuttle cover (page 209).
7. Adjust the hammer phasing (page 179.)
8. Return the printer to normal operation (page 159).

Table of Contents

Other manuals for IBM 6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 6400 Series and is the answer not in the manual?

IBM 6400 Series Specifications

General IconGeneral
BrandIBM
Model6400 Series
CategoryPrinter
LanguageEnglish

Related product manuals