354 Safety Inspection Guide
Customer Power Source Service Check
Use an ECOS Electrical Safety Tester (P/N 6339695) in the United States or
a similar safety tester in other countries.
NOTE: The ECOS tester will trip ground fault detector protected outlets.
This is a good test of the ground fault detector. Reset the outlet as
needed.
Plug the ECOS meter into the customer’s outlet. Follow the instructions
supplied with the meter to test for the following:
1. Wiring errors
2. Low voltage
3. Neutral to ground short
4. Ground path impedance
5. Neutral impedance
NOTE: The customer is responsible for correcting problems with the power
source. Inform the IBM Installation Planning Representative (IPR) of
any problems with the customer’s power source.
Each branch circuit must be grounded for safety and correct operation of the
printer. This ground must be connected either to the electrical service ground
or to a suitable building ground. The printer power cable has a green or
green/yellow insulated grounding conductor. This is
not
a neutral.
Power Cable
1. Make sure the power cable is not damaged.
2. Make sure the power plug is the correct type.

Table of Contents

Other manuals for IBM 6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 6400 Series and is the answer not in the manual?

IBM 6400 Series Specifications

General IconGeneral
BrandIBM
Model6400 Series
CategoryPrinter
LanguageEnglish

Related product manuals