2624-704
Explanation: Error Log Analysis indicates that this adapter has failed due to a unrecoverable internal parity error
Replace the 4X PCI-E DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v FFC_2624
2624-705
Explanation: Error Log Analysis indicates that this adapter has failed due to a internal error. Replace the 4X PCI-E
DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v FFC_2624
2624-706
Explanation: Error Log Analysis indicates that this adapter has failed due to a memory error. Replace the 4X PCI-E
DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v FFC_2624
2624-XXX
Explanation: Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter. Go to Performing the checkout
procedure.
Response:
Failing Item:
v FFC_2624
2625-101
Explanation: Configuration failure. Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625