26D2-102
Explanation: An unrecoverable media error occurred. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-104
Explanation: The motor failed to restart. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-105
Explanation: The drive did not become ready. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-106
Explanation: The electronics card test failed. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-108
Explanation: The bus test failed. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-110
Explanation: The media format is corrupted. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-102 26D2-110
362 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide