Chapter 4. IBM System Storage DS planning and configuration 249
4.10.6 Cache parameters
The Storage Manager utility enables various cache settings to be configured:
Specify the DS5000 system wide settings:
– Start and stop cache flushing levels (this setting will affect all arrays and logical drives
created on the system)
– Cache Block size
Specify settings per logical drive:
– Read caching
– Cache read-ahead multiplier
– Write caching or write-through mode (write caching disabled)
– Enable or disable write cache mirroring
Figure 4-112 shows the typical values when using the Create Logical Drive Wizard. With the
Storage Manager, cache settings can be specified for each logical drive independently, giving
greater flexibility.
Figure 4-112 Default values used by the Create Logical Drive Wizard
Changing cache settings
This can be achieved at logical drive and subsystem levels.
Note: We recommend that the values are manually set during creation to suit the
performance needs of the logical drive. These settings can be changed after logical drive
creation for tuning purposes.