314 IBM Midrange System Storage Hardware Guide
19.After the configuration is updated, go to the Main menu, select System, and run the
configuration test. When the test is complete, the date and time of the last run is shown, as
shown in Figure 6-23.
Figure 6-23 RSM configuration test done
6.2.4 Configuring SNMP traps in Storage Manager
To allow the DS storage subsystem management workstation to send SNMP traps to the
RSM server, set the RSM server as your SNMP traps destination in the Storage Manager
client.
To configure the DS Storage Manager to send SNMP alerts for each defined storage
subsystem in RSM to the RSM host, perform these steps:
1. Open the Enterprise management window of the Storage Manager.
2. Right-click a DS storage subsystem. In the Connect menu, click Configure Alerts....
3. In the Configure Alerts window, click the SNMP tab.
4. Enter the host name or the IP address of the RSM host in the trap destination field and
click Add (Figure 6-24 on page 315). Do not change the SNMP community name (the
default is
public).