370 IBM Midrange System Storage Hardware Guide
We can choose to save specific elements of the configuration (Figure 7-39).
Figure 7-39 Saving configuration elements
Select the desired configuration elements, click Yes, and select a file name and destination
folder in which to the save file. Make sure not to use a directory located on a DS storage
subsystem disk, or you might not be able to access it when needed.
The script created can be used to replicate the configuration of the DS storage subsystem.
You can apply the configuration to the destination subsystem for all the saved elements, or
any particular element. The script consists of the following information:
򐂰 Storage subsystem settings
User label
Media scan rate
Cache block size
Cache flush start
Cache flush stop
Default host type
Failover alert delay
򐂰 Logical drive configuration
RAID level
User label
Owning controller
–Segment size
Capacity
Cache flush modifier
Read-ahead multiplier
Modification priority
Caching without batteries enabled/disabled