057 (continued)
ARE THE VOLTAGES CORRECT?
Yes No
058
Replace the power supply.
059
– Power off the system unit.
– Check all lines of the hard disk drive signal cable for continuity.
DO ALL LINES HAVE CONTINUITY?
Yes No
060
Replace the failing signal cable.
061
Check the jumper position on the secondary hard disk drive. If
correct, replace the failing secondary hard disk drive.
062
(From step 055)
The Advanced Diagnostic tests have finished without detecting a failure. If
you suspect an intermittent problem, start an error log. If you need
instructions, refer to “Error Log” on page 3-9.
063
(From step 025)
– Power off the system unit and wait 10 seconds.
– Disconnect the power cable from the hard disk drive.
– Power on the system unit.
– Check the voltages at the hard disk drive end of the power cable.
(Step 063 continues)