043 (continued)
Power on the system unit.
Make a note of any error messages, if present, and press the Esc key.
IS THE SCREEN BLANK (DARK)?
Yes No
044
Go to Step 065 on page 2-109.
045
(From step 105)
Power off the system unit.
Disconnect the power cables to the system board and drives.
Power on the system unit.
Check the voltages at the power supply connectors to the system board
as indicated.
– PWR GOOD
– +3.75 to 6.25 V dc
– +9 to 15 V dc
– -9 to 15 V dc
GND
– -3.75 to 6.25 V dc
– +3.75 to 6.25 V dc
Figure 2-13. System Board Power Supply Connectors
ARE THE VOLTAGES CORRECT?
Yes No
046
(Step 046 continues)
Diagnostic Information 2-105