v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 Types 4362 and 4363,” on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
289 A DIMM has been disabled by system.
1. Make sure that the DIMM is installed correctly
(see “Installing a memory module” on page 102).
2. Replace the DIMM.
3. (Trained service technician only) Replace the
system board.
301 Keyboard or keyboard controller error.
1. If you have installed a USB keyboard, run the
Configuration/Setup Utility program and enable
keyboardless operation to prevent the POST error
message 301 from being displayed during startup.
2. Reseat the keyboard cable.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Keyboard
b. (Trained service technician only) System
board
303 Keyboard controller failure.
1. Reseat the keyboard.
2. Replace the keyboard.
3. (Trained service technician only) Replace the
system board.
602 Invalid diskette boot record
1. Replace the diskette.
2. Reseat the diskette drive cables.
3. Replace the diskette drive.
604 Internal diskette drive error
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the diskette drive signal cables.
3. Replace the diskette drive.
962 Parallel port configuration error
1. Run the Configuration/Setup Utility program and
make sure that the parallel port setting is correct.
2. (Trained service technician only) Replace the
system board.
1162 Serial port error
1. Run the Configuration/Setup Utility program and
make sure that the serial port settings are correct.
2. (Trained service technician only) Replace the
system board.
Chapter 2. Diagnostics 21

Table of Contents

Other manuals for IBM System x3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3200 and is the answer not in the manual?

IBM System x3200 Specifications

General IconGeneral
Form FactorTower
NetworkIntegrated Gigabit Ethernet
ProcessorIntel Xeon 3000 sequence, Intel Pentium Dual-Core processor, Intel Celeron processor
Processor CoresDual-Core
ChipsetIntel 3000
MemoryUp to 8GB DDR2
Memory Slots4
StorageSATA HDD
RAID SupportRAID 0, 1
Drive Bays4 internal 3.5-inch

Related product manuals