“Recovering the server firmware” on page 109. After you have recovered the
firmware in the primary bank, complete the following steps:
1. Restart the server.
2. When the prompt Press F3 to restore to primary is displayed. Press F3 to
recover the primary bank. Pressing F3 will restart the server.
Nx boot failure
Configuration changes, such as added devices or adapter firmware updates, and
firmware or application code problems can cause the server to fail POST (the
power-on self-test). If this occurs, the server responds in either of the following
ways:
v The server restarts automatically and attempts POST again.
v The server hangs, and you must manually restart the server for the server to
attempt POST again.
After a specified number of consecutive attempts (automatic or manual), the Nx
boot failure feature causes the server to revert to the default UEFI configuration and
start the Setup utility so that you can make the necessary corrections to the
configuration and restart the server. If the server is unable to successfully complete
POST with the default configuration, there might be a problem with the system
board.
To specify the number of consecutive restart attempts that will trigger the Nx boot
failure feature, in the Setup utility, click System Settings → Operating Modes →
POST Attempts Limit. The available options are 3, 6, 9, and 255 (disable Nx boot
failure).
Chapter 3. Diagnostics 113