Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Types 4255, 7945, and 7949 server,” on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Sensor CPU nOverTemp has
transitioned to non-recoverable
from a less severe state.
(n = microprocessor number)
Error A sensor has changed to
Nonrecoverable state from a less
severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffles are in
place and correctly installed,
and that the server cover is
installed and completely
closed.
2. Make sure that the heat sink
for microprocessor n is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
Sensor CPU nOverTemp has
transitioned to critical from a
non-recoverable state.
(n = microprocessor number)
Error A sensor has changed to Critical
state from Nonrecoverable state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffles are in
place and correctly installed,
and that the server cover is
installed and completely
closed.
2. Make sure that the heat sink
for microprocessor nis
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
Sensor CPU nOverTemp has
transitioned to non-recoverable.
(n = microprocessor number)
Error A sensor has changed to
Nonrecoverable state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffles are in
place and correctly installed,
and that the server cover is
installed and completely
closed.
2. Make sure that the heat sink
for microprocessor n is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
Chapter 3. Diagnostics 119

Table of Contents

Other manuals for IBM System x3650 M3 4255

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M3 4255 and is the answer not in the manual?

IBM System x3650 M3 4255 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel 5520
Max Processors2
ProcessorIntel Xeon 5600 series
MemoryUp to 192GB DDR3
Network InterfaceDual-port Gigabit Ethernet
Hard Drive BaysUp to 16 x 2.5" or 6 x 3.5"
RAID SupportRAID 0, 1, 10
Memory Slots18 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals