EasyManuals Logo

IBM System x3650 M3 4255 Service Guide

IBM System x3650 M3 4255
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Types 4255, 7945, and 7949 server,” on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Redundancy Bckup Mem Status
has been reduced.
Error Redundancy has been lost and is
insufficient to continue operation.
1. Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
Sensor Planar Fault has
transitioned to critical from a less
severe state.
Error A sensor has changed to Critical
state from a less severe state.
(Trained service technician only)
Replace the system board.
IMM Network Initialization
Complete.
Info An IMM network has completed
initialization.
No action; information only.
Certificate Authority %1 has
detected a %2 Certificate Error.
(%1 = IBM_CertificateAuthority
.CADistinguishedName;
%2 = CIM_PublicKeyCertificate
.ElementName)
Error A problem has occurred with the
SSL Server, SSL Client, or SSL
Trusted CA certificate that has
been imported into the IMM. The
imported certificate must contain
a public key that corresponds to
the key pair that was previously
generated by the Generate a
New Key and Certificate
Signing Request link.
1. Make sure that the certificate
that you are importing is
correct.
2. Try importing the certificate
again.
Ethernet Data Rate modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)
Info A user has modified the Ethernet
port data rate.
No action; information only.
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
FullDuplex;
%2 = CIM_EthernetPort.
FullDuplex;
%3 = user ID)
Info A user has modified the Ethernet
port duplex setting.
No action; information only.
Ethernet MTU setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
ActiveMaximum
TransmissionUnit;
%2 = CIM_EthernetPort.
ActiveMaximum
TransmissionUnit; %3 = user ID)
Info A user has modified the Ethernet
port MTU setting.
No action; information only.
146 IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M3 4255

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M3 4255 and is the answer not in the manual?

IBM System x3650 M3 4255 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel 5520
Max Processors2
ProcessorIntel Xeon 5600 series
MemoryUp to 192GB DDR3
Network InterfaceDual-port Gigabit Ethernet
Hard Drive BaysUp to 16 x 2.5" or 6 x 3.5"
RAID SupportRAID 0, 1, 10
Memory Slots18 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals