v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Types 4255, 7945, and 7949 server,” on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
3048006 Booted secondary (backup) server firmware
image because of ABR
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
primary server firmware settings.
2. Turn off the server and remove it from the power
source.
3. Reconnect the server to the power source, and
then turn on the server.
305000A RTC date/time is incorrect
1. Adjust the date and time settings in the Setup
utility, and then restart the server.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
3058001 System configuration invalid
1. Run the Setup utility, and select Save Settings.
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Reseat the following components one at a time in
the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be reseated by a trained service
technician only)
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be replaced by a trained service
technician only)
c. (Trained service technician only) System
board
38 IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide