v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7979 and 1914 server,” on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
3-3-3 No operational memory in system.
1. Make sure that the server contains the
correct number of DIMMs, in the correct
order; install or reseat the DIMMS; then,
restart the server three times.
Important: You must restart the server
three times to reset the configuration
settings to the default configuration (the
memory connector or bank of connectors
enabled).
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only)
System board
4-4-4 Optional system management adapter not
installed in Remote Supervisor Adapter II
SlimLine connector or not functioning
correctly.
1. Make sure that the Remote Supervisor
Adapter II SlimLine is installed in the
Remote Supervisor Adapter II SlimLine
connector.
2. Reseat the Remote Supervisor Adapter II
SlimLine.
3. Replace the following components one at
a time, in the order shown, restarting the
server each time:
v Remote Supervisor Adapter II SlimLine
v (Trained service technician only) System
board
Two short beeps Information only, the configuration has
changed
1. Run the diagnostics programs to verify that
all components are working.
2. Run the Configuration/Setup Utility
program, save the configuration, and
restart the server.
Three short beeps Possible memory prloblem.
1. Reseat the DIMMs.
2. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
22 IBM System x3650 Type 7979 and 1914: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 Type 7979 and is the answer not in the manual?

IBM System x3650 Type 7979 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650 Type 7979
CategoryServer
LanguageEnglish

Related product manuals