v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7979 and 1914 server,” on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
00012000 Processor machine check error.
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board
00019701 Processor 1 failed BIST.
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board
01298001 No update data for processor 1.
1. Update the BIOS code again.
2. (Trained service technician only) Replace the
microprocessor.
01298101 Bad update data for processor 1.
1. Update the BIOS code again.
2. (Trained service technician only) Replace the
microprocessor.
I9990301 Hard disk drive boot sector error.
1. Reseat the following components:
a. Hard disk drive
b. Hard disk drive backplane cable
2.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive backplane cable
b. Hard disk drive
c. Hard disk drive backplane
d. (Trained service technician only) System
board
I9990305 Operating system not found. Run the Configuration/Setup Utility program to make
sure that a bootable operating system is installed on
one or more devices that are listed in the boot order.
I9990650 AC power has been restored.
1. Check the power cables.
2. Check for interruption of the power supply.
Chapter 2. Diagnostics 33

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 Type 7979 and is the answer not in the manual?

IBM System x3650 Type 7979 Specifications

General IconGeneral
Form Factor2U Rack
Processor SpeedUp to 3.0 GHz
ChipsetIntel 5000P
MemoryUp to 48 GB DDR2
RAM Slots12 DIMM slots
NetworkDual Gigabit Ethernet
Drive BaysHot-swap 3.5" HDD bays
RAID SupportRAID 0, 1, 10
Power SupplyDual 835W hot-swap
Expansion Slots6 PCIe
Operating System SupportWindows Server, Linux, VMware
StorageSAS or SATA HDDs