v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7979 and 1914 server,” on page 79 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System event/error log message Action
+5v critical over voltage fault
1. Remove the following devices, which are powered by 5 volts:
v All PCI adapters
v USB devices
v CD-RW/DVD drive
v Tape drive, if one is installed
v Hard disk drive backplane
2.
Reinstall each I/O device removed in step 1, one at a time,
restarting the server each time, to isolate a defective device.
Replace any defective device.
3. If the error continues, replace the power backplane. Restart the
server.
4. If the error continues, (trained service technician only) replace
the system board.
+5v critical under voltage fault
1. Remove the following devices, which are powered by 5 volts:
v All PCI adapters
v USB devices
v CD-RW/DVD drive
v Tape drive, if one is installed
v Hard disk drive backplane
2.
Reinstall each I/O device removed in step 1, one at a time,
restarting the server each time, to isolate a defective device.
Replace any defective device.
3. If the error continues, replace the power backplane. Restart the
server.
4. If the error continues, (trained service technician only) replace
the system board.
5V fault
1. Remove the following devices, which are powered by 5 volts:
v All PCI adapters
v USB devices
v CD-RW/DVD drive
v Tape drive, if one is installed
v Hard disk drive backplane
2.
Reinstall each I/O device removed in step 1, one at a time,
restarting the server each time, to isolate a defective device.
Replace any defective device.
3. If the error continues, replace the power backplane. Restart the
server.
4. If the error continues, (trained service technician only) replace
the system board.
+2.5v critical over voltage fault Information only
+2.5v critical under voltage fault Information only
+1.8v critical over voltage fault Information only
70 IBM System x3650 Type 7979 and 1914: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 Type 7979 and is the answer not in the manual?

IBM System x3650 Type 7979 Specifications

General IconGeneral
Form Factor2U Rack
Processor SpeedUp to 3.0 GHz
ChipsetIntel 5000P
MemoryUp to 48 GB DDR2
RAM Slots12 DIMM slots
NetworkDual Gigabit Ethernet
Drive BaysHot-swap 3.5" HDD bays
RAID SupportRAID 0, 1, 10
Power SupplyDual 835W hot-swap
Expansion Slots6 PCIe
Operating System SupportWindows Server, Linux, VMware
StorageSAS or SATA HDDs