Table 41. FCs for the frame models of the TS4500 tape library (continued)
FC Model CSU Description
1909 L25, L55, D25, D55 No Single power source bifurcated cable
This feature allows attachment of a
powered frame to a single outlet while it
also maintains drive redundant power.
1951 D25, D55, L25, L55, S25, S55 No Power distribution units
This feature provides two PCAs, mounting
hardware including rack brackets, and
internal power cables.
FC 1951 supports any combination of up to
3 pairs of power cords for FC 4875 on the
same frame and FC 9989 on adjacent
frames.
Corequisite: One power cord feature (FC
9954 thru 9959 or 9966)
2002 L25, L55 No 1-2 Frame Flex Track A Cable
2006 L25, L55 No 3-6 Frame Flex Track A Cable
2014 L25, L55 No 7-14 Frame Flex Track A Cable
2018 L25, L55 No 9-18 Frame Flex Track A Cable
2071 L25, L55 No Flex Track Guide
This includes AXY, AXY plate, ASC to Flex
track cable and new end stops.
2072 D25, D55, S25 S55, Sx4 No Flex Track Guide for Expansion Frame
2309 xx5 No TS4500 Accessor Refresh
Provides complete accessor assembly with
HD grippers to Lxx models or models with
FC 1442.
Prerequisite: FC 2071, 2072, or 9071, 9072 .
2402 L25, L55 No 1-2 Frame Flex Track B Cable
2406 L25, L55 No 3-6 Frame Flex Track B Cable
2414 L25, L55 No 7-14 Frame Flex Track B Cable
2418 L25, L55 No 9-18 Frame Flex Track B Cable
2704 L25, L55 No Console expansion 26-port Ethernet
switch/rack mount
This feature provides a 26-port Ethernet
switch and attachment cable for connection
to an IMC as an centralized system
console.
Up to 24 extra connections of FC 2715 are
provided by this feature. FC 2704 is
supported on Lx5 models to allow other
products to share the IMC.
Chapter 2. Planning 101