185
18
CONTROL COMMAND
D Command table (continued)
Cmd.
Sub cmd.
Data Description
15 01 00 Read squelch status (squelch close)
01 Read squelch status (squelch open)
02 0000 to
0255
Read S-meter level
(0000=S0,0120=S9,0240=S9+60dB)
11 0000 to
0255
Read RF power meter
(0000=0%,0141=50%,0215=100%)
12 0000 to
0255
Read SWR meter
(0000=SWR1.0,0041=SWR1.5,
0081=SWR2.0,0120=SWR3.0)
13 0000 to
0255
Read ALC meter
(0000=Min.to0120=Max.)
14 0000 to
0255
Read COMP meter
(0000=0dB,0120=15dB,0240=30dB)
16 02 00 Send/read Preamp OFF
01
Send/read Preamp ON (144/430/1200 MHz)
Send/read Preamp 1 ON (HF/50 MHz)
02 Send/read Preamp 2 ON (HF/50 MHz)
12 01 Send/read AGC FAST
02 Send/read AGC MID
03 Send/read AGC SLOW
22 00 Send/read Noise Blanker OFF
01 Send/read Noise Blanker ON
40 00 Send/read Noise Reduction OFF
01 Send/read Noise Reduction ON
41 00 Send/read Auto Notch function OFF
01 Send/read Auto Notch function ON
42 00 Send/read Repeater tone OFF
01 Send/read Repeater tone ON
43 00 Send/read Tone squelch OFF
01 Send/read Tone squelch ON
44 00 Send/read Speech compressor OFF
01 Send/read Speech compressor ON
45 00 Send/read Monitor function OFF
01 Send/read Monitor function ON
46 00 Send/read VOX function OFF
01 Send/read VOX function ON
47 00 Send/read BK-IN function OFF
01 Send/read Semi BK-IN function ON
02 Send/read Full BK-IN function ON
48 00 Send/read Manual notch function OFF
01 Send/read Manual notch function ON
4A 00 Send/read AFC function OFF
01 Send/read AFC function ON
4B 00 Send/read DTCS OFF
01 Send/read DTCS ON
4C 00 Send/read VSC function OFF
01 Send/read VSC function ON
4F 00 Send/read Twin Peak Filter OFF
01 Send/read Twin Peak Filter ON
50 00 Send/read Dial lock function OFF
01 Send/read Dial lock function ON
55 00 Send/read 1st IF filter 3 kHz
01 Send/read 1st IF filter 6 kHz
02 Send/read 1st IF filter 15 kHz
56 00 Send/read DSP filter type SHARP
01 Send/read DSP filter type SOFT
57 00 Send/read manual notch width WIDE
01 Send/read manual notch width MID
02 Send/read manual notch width NAR
58 00 Send/read SSB transmit bandwidth WIDE
01 Send/read SSB transmit bandwidth MID
02 Send/read SSB transmit bandwidth NAR
Cmd.
Sub cmd.
Data Description
16 59 00 Send/read Sub band OFF
01 Send/read Sub band ON
5A 00 Send/read Satellite mode OFF
01 Send/read Satellite mode ON
5B 00 Send/read DSQL/CSQL OFF (DV mode
only)
01 Send/read DSQL ON (DV mode only)
02 Send/read CSQL ON (DV mode only)
17 see p. 191 Send CW messages
19 00 Read the transceiver ID
1A 00 see p. 195 Send/read memory contents
01 see p. 191 Send/read band stacking register con-
tents
02 see p. 191 Send/read memory keyer contents*
1
03 00 to 49 Send/read the selected filter width
(AM:00=200Hzto49=10kHz;
otherthanAMmodes:00=50Hzto
40/31=3600Hz/2700Hz)
04 00 to 13
Send/read the selected AGC time constant
(00=OFF,AM:01=0.3sec.to13=8.0sec.
SSB/CW/RTTY:01=0.1sec.to13=6.0sec.)
05 0001 0000 to
0255
Send/read LCD contrast level
(0000=0%(low)to0255=100%(high))
0002 0000 to
0255
Send/read LCD backlight brightness level
(0000=0%(dark)to0255=100%(bright))
0003 0000 to
0255
Send/read beep level
(0000=0%to0255=100%)
0004 00 Send/read beep level limit OFF
01 Send/read beep level limit ON
0005 00 Send/read confirmation beep OFF
01 Send/read confirmation beep ON
0006 00 Send/read band edge beep OFF
01 Send/read band edge beep ON
(Beep sounds with a default band)
02 Send/read band edge beep with user set-
ting ON
03 Send/read band edge beep with user set-
ting/TX limit ON
0007 0050 to
0200
Send/read beep audio frequency for MAIN
Band
(0050=500Hzto0200=2000Hz)
0008 0050 to
0200
Send/read beep audio frequency for SUB
Band
(0050=500Hzto0200=2000Hz)
0009 00 Send/read Auto selection for [RF/SQL]
01 Send/read SQL selection for [RF/SQL]
02
Send/read RF+SQL selection for [RF/SQL]
0010 00 Send/read Meter Peak Hold function OFF
01 Send/read Meter Peak Hold function ON
0011 00 Send/read FM/DV Center Error function
OFF
01 Send/read FM/DV Center Error function
ON
0012 00 Send/read Time-Out Timer OFF
01 Send/read 3 min. Time-Out Timer
02 Send/read 5 min. Time-Out Timer
03 Send/read 10 min. Time-Out Timer
04 Send/read 20 min. Time-Out Timer
05 Send/read 30 min. Time-Out Timer
0013 00 Send/read PTT Lock function OFF
01 Send/read PTT Lock function ON
0014 00 Send/read Quick Split function OFF
01 Send/read Quick Split function ON
0015 see p. 192 Send/read Split offset frequency