EasyManua.ls Logo

Icom IC-7400 - I Programming Scan Edges

Icom IC-7400
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
7
MEMORY OPERATION
2001 NEW 2001 NEW
Programming scan edges
Memory channels P1 and P2 are the program scan
edges. They are used to program an upper and lower
frequency for programmed scan (p. 70). By default, P1
is programmed with 0.50000 MHz and P2 is pro-
grammed with 29.99999 MHz. If P1 and P2 are pro-
grammed with the same frequencies, programmed
scan will not proceed.
[EXAMPLE]: Programming 14.00000 MHz into P1
and 14.35000 MHz into P2.
q Push [V/M] to select VFO mode, if necessary.
w Rotate [M-CH] to select scan edge P1.
e Rotate the tuning dial to set 14.00000 MHz as the
lower frequency.
r Push [MW] for 1 sec. to program 14.00000 MHz
into scan edge P1.
3 beeps are emitted.
t Rotate [M-CH] to select scan edge P2.
y Rotate the tuning dial to set 14.35000 MHz as the
upper frequency.
u Push [MW] for 1 sec. to program 14.35000 MHz
into scan edge P2.
3 beeps are emitted.
When programmed scan is activated (p. 70) scanning
will search the frequencies between 14.00000 MHz and
14.35000 MHz for signals.
[V/M]
Tuning dial
[M-CH]
[MW]
After steps w to r
After steps t to u
IC-7400.qxd 02.4.2 11:35 Page 65