8: I
NSTRUCTIONS
/F
UNCTION
B
LOCKS
R
EFERENCE
8-8 S
MART
AXIS P
RO
/L
ITE
U
SER
'
S
M
ANUAL
FT9Y-B1378
Note 1: When using RAMP1 in single-pulse output mode, PULS3 and PWM3 cannot be used. When using RAMP2 in single-pulse output mode,
PULS4 and PWM4 cannot be used.
Note 2: When using RAMP1 or ARAMP1 in dual-pulse output mode, RAMP2 or ARAMP2 cannot be used.
“X” indicates that the instruction is supported.
Group Symbol
FT1A-12 FT1A-24 FT1A-40 FT1A-48
FT1A-
Touch
AC DC AC DC AC DC AC DC
Pulse
PULS1 X X X
PULS2 X X X
PULS3
X
(Note1)
XX
PULS4
X
(Note1)
XX
PWM1 X X X
PWM2 X X X
PWM3
X
(Note1)
XX
PWM4
X
(Note1)
XX
RAMP1 X X X
RAMP2
X
(Note2)
X
(Note2)
X
(Note2)
ZRN1 X X X
ZRN2 X X X
ARAMP1 X X X
ARAMP2
X
(Note2)
X
(Note2)
X
(Note2)
Dual / Teaching
Timer
DTML XXXXX X X X X
DTIM XXXXX X X X X
DTMH XXXXX X X X X
DTMS XXXXX X X X X
TTIM XXXXX X X X X
Trigonometric
Function
RAD XXXXX X X X X
DEG XXXXX X X X X
SIN XXXXX X X X X
COS XXXXX X X X X
TAN XXXXX X X X X
ASIN XXXXX X X X X
ACOS XXXXX X X X X
ATAN XXXXX X X X X
Logarithm / Power
LOGE XXXXX X X X X
LOG10 XXXXX X X X X
EXP XXXXX X X X X
POW XXXXX X X X X
File Data
Processing
FIFOF XXXXX X X X X
FIEX XXXXX X X X X
FOEX XXXXX X X X X
NDSRC XXXXX X X X X
Clock
TADD XXXXX X X X X
TSUB XXXXX X X X X
HTOS XXXXX X X X X
STOH XXXXX X X X X
HOUR XXXXX X X X X
Ethernet
Instructions
ETXD XXX X X X
ERXD XXX X X X
Data Logging
DLOG X X X X
TRACE X X X X
Script Instructions SCRPT XXXXX X X X X