3D sensor
48
13.2.5 a Command
Command
a<application number>
Description Activates the selected
application
Type Action
Reply *
! Application not available
<application number>
contains wrong value
External application switching
activated
Device is in an invalid state
for this command, e.g.
configuration mode
? Invalid command length
Note <application number>
2 digits for the application
number as decimal value
13.2.6 A? Command
Command
A?
Description Requests the occupancy of the
application list
Type Request
Reply <amount><t><number active
application><t>
...
<number><t><number>
? Invalid command length
! Invalid state (e.g. no application
active)
Note <amount>
char string with 3 digits for the
amount of applications saved on
the device as decimal number
<t>
tabulator (0x09)
<number active application>
2 digits for the active application
<number>
2 digits for the application
number
The active application is
repeated within the application
list.