® Setting up the DEGAUSS (demagnetization) timer
Divide the monitor into IO blocks and set the DEGAUSE time at
which degaussing is automatically pedbrmed at the time of power
on within a range ofO to 9.
It is provided to delay automatic degaussing that works
automatically at the time of power on at a unit of 0.5 second,
thereby minimizing 111sh current that occurs when turning on
power supply to the rack all at once.
For details, reter to 4-11 (4) (8).
a) Select "Item 7" on MENU 2 by means of T key, and press
ENT key.
f(!)
MENU2 <MODE> VER:07. 1
~
1. CENT. MARKER ON
2. MARKER COLOR
3. ASPECT 16:9
4. SCAN UNDER
5. SET UP OFF
ENT 6. REMOTE NO. 02
7. D~.,...(D
~
-HEXT -• (MENU)
SELECT -• (ENT) EX I T-(ESC)
b) Set monitor to O to 9 groups by means of TA keys, and
finalize with ENT key.
f ( A) MENU2 <MODE> VER: 07. 1
1. CENT. IMRKER ON
....._ 2. MARKER COLOR
-----~- ASPECT 16:9
,0 I 4-......sQAN UNDER
5. SEl'1:JR.._ OFF
ENT 6. REMOTE ND:---....,_ 02
7. DEGAUSS TM. i:S)
NEXT (MENU)
SELECT -• (ENT) EX I T- (ESC)
c) Exit MENU screen with ESC key, press END key to cancel the
remote control mode. Thus setting has been completed.
HTM-1505R/HTM-1505CS
27