36 Keypads
Anti-intrusion control panels
6-6-5
View
From the keypad, the user can view the current status of some of the system elements:
the events log (alarms, faults, arm/disarm operations, etc.), which shows the chronology
with which the events occurred and were restored
the status of the Nexus GSM communicator
the control panel power-supply voltage, its firmware version and model
the electrical status of the zones (stand-by, alarm, short-circuit, tamper) and their
bypassed status
activation status of the outputs
activation status of the timers
any faults present (refer to Appendix B, Fault signals)
To view these statuses:
activate the shortcuts associated with keys , ..., (shown on the display) with or
without code entry:
access the “View” section of the User menu by entering a valid PIN.
User access to the information in the “Logs” section is filtered. For example, a user can only
view the zone alarms relating to the partitions the entered user code and keypad concerned
have in common.
Press keys and to scroll the chronological events list.
For some events, pressing the button will allow you to view the respective details.
Table 6-13: Shortcut for viewing from a keypad
Shortcut User menu section Operation
View
Access the section with the list of items
that can be viewed.
View events log n.28
Events log
Events log
View alarms log n.29
Alarms log
Alarms log
View faults log n.30
Faults log
Faults log
View arm/dis-
arm operations
n.31
Arm/Disarm ops.
Arm/Disarm log
Nexus status
menu
n.16
Nexus status
Status of Nexus GSM communicator
View system sta-
tus
n.32
System status,
Batt
the voltage measured on the battery
Pow.
the control panel power supply voltage
Aux x
the voltage measured on terminal “AUX x”
I-BUS
the voltage measured on terminal “+” of
the I-BUS
View zone status n.33
Zone status
Zone status
View faults n.36
Faults ongoing
Ongoing fault
PanelVersion
the firmware version and the control panel
model
User Code
Voice functions
Activations
View
VIEW
Events log
Alarms log
Faults log
ID Event : 1234
Event Num.: 5678
Valid code
User Code
KEYP. 001
18:23 01/01/2019