User’s manual
Keypads 37
NEXUS STATUS
ZONE STATUS
6-6-6
Outputs management
This section allows you to activate/deactivate manually the outputs the code is authorized to
work on.
The user can implement output activations via the keypad in two ways:
• activate the shortcuts associated with keys , ..., (shown on the display) with or
without code entry:
• access the “Outputs ON/OFF” section of the user menu by entering a valid PIN.
Once the output has been selected, it can be activated by the key and deactivated by the
key.
If the output is a dimmer output, you can increase or decrease its power supply by means of
keys and .
6-6-7
Change date and time
The keypads have a section where you can set the date and time of the control panel and the
format.
The user can operate via the keypad in two ways:
• activate the “Date/Time” shortcut (shortcut n.35), associated with one of the keys ,
..., shown on the display, with or without code entry
Table 6-14: View Nexus status on the keypad
Line Display View
1
• Mobile network provider (on the left side)
• “--” means that the Nexus is connected to the BUS
• “C” means that data transfer is in progress
• data network technology (on the right side)
G, GPRS service
3G, UMTS service
H, HSPA service
2
GSM signal reception (value between 1 and 100)
3
balance, at the last operation (expressed in the local currency)
4
Faults present, in this case it is necessary to access the “View-
Faults” section for details.
Table 6-15: View zone status from keypad
Line Display View
1
Zone description
2
Zone status (“Standby”, “Alarm”, “Short-circuit”, “Tamper”)
and its activation status (“unbypassed” - capable of generating
alarms, or “bypassed” - incapable of generating alarms)
3
Indications that vary depending on the device type:
• wireless zone; level of wireless signal reception (from 0 to
7)
• Air2-FD100 smoke detector; level of wireless signal and
level of smoke present in the sensing chamber, expressed
in mdB/m
4
Level of contamination present in the smoke detection
chamber of Air2-FD100 smoke detector (%)
Table 6-16: Shortcut for output activations from a keypad
Shortcut User menu section Operation
ON/OFF output
menu
Outputs ON/OFF
Access the section with the list of
available outputs
Activate output n.5
Activates the output programmed for the
shortcut
Deactivate output n.6
Deactivates the output programmed for
the shortcut
Outputs ON/OFF
RELAY 001
OUTPUT 001
OUTPUT 002
User Code
Activations
View
Outputs ON/OFF
Outputs ON/OFF
RELAY 001
OUTPUT 001
OUTPUT 002