46 Keypads
Anti-intrusion control panels
Language - for the selection of the language used by the Alien keypad
Temperature adjustment - for the adjustment of the temperature shown on the display
View partitions - for the visualization of the operating status of the partitions on the
bottom bar of the display
Exit time - enables/disables the audible signal during exit time
Entry time - enables/disables the audible signal during entry time
Bell - enables/disables the audible signal for the bell function
Temperature - enables/disables the visualization of the temperature on the display
Tamper - enables/disables the device tamper function (Alien/G only)
Maps - enables/disables the automatic start up of the graphic maps application when the
keypad is in stand-by
Show scenario with code - enables/disables the request for user-code entry when the
user taps the lower bar on the home page to view the active scenarios.
Emergency lights - if enabled, in the event of mains power failure the keypad will
increase brightness to its maximum value and will hold this status until the mains power
restores to normal
If the Prime control panel is in maintenance status, a list of the following parameters will be
shown:
Keypad address
Keypad address - this is the address of the Alien keypad and its integrated reader
Tamper - enables/disables the device tamper protection (for Alien/G this option is shown
also when the control panel is not in maintenance status); if tamper is disabled, the upper
tool bar on the home page will show the icon opposite.
You can select the parameter by means of + and - buttons. To confirm changes and exit the
section press the SAVE button.
Note
English is the default language of the Alien keypad.
6-7-10
Change code PIN
To change the PINs of the user codes via the Alien keypad, access the “Settings” section,
enter a valid user code, then go to the“Date/Time - Change PIN - Change Tel. Numbers”
section and select “Change PIN”.
Select the code you desire from those available on the list. The next step is to change the
code by means of the buttons on the screen and confirm changes by pressing the OK button.
6-7-11
Edit telephone numbers
To edit telephone numbers via the the Alien keypad, access the “Settings” section, enter a
valid user code, go to the“Date/Time - Change PIN - Change Tel. Numbers”, then to the “ Tel.
Numbers” section.
Select the telephone number you desire from those available on the list. The next step is to
edit the number using the screen buttons and confirm changes by pressing the OK button.
6-7-12
Overtime request
Overtime requests via Alien keypads can be activated through the “Menu” section after
entering a valid user code and accessing the “Actions” section.
This section contains a list of control panel commands which can be activated by pressing the
ON button, amongst which “Overtime request”.
6-7-13
Thermostat
The Alien keypad Thermostat” functions can be managed via the “Climate” section.
This is the section relative to the operating mode of the thermostat.
Press the Back button accesses a page containing buttons for the selection of the 5
operating modes available.
Manual
•Day mode
Week
Antifreeze
•OFF