Installation and programming manual
Apollo devices 69
C.6 Modules
C.7 DIN RAIL Modules
C.8 Modules with Isolators
C.9 Configuring APOLLO devices
You must address all Apollo devices manually, and then allow the Smart Light panel to learn the assigned
addresses.
Note: Each loop supports up to 126 devices.
Model Name Description
55000-809 XP95 Switch Monitor Plus Module with 1 Input with delay and reset output for waterflow
detectors (waterflow alarm)
55000-810 XP95 Switch Monitor Single Input Module
55000-813 XP95 Zone Monitor Conventional Detector Interface Module
55000-818 XP95 Input/Output Module Module with 1 Relay Output + 1 Supervised Input + 1 Non-
Supervised Input
55000-819 XP95 Output Module Module with 1 Relay Output
55000-823 XP95 Sounder Control Unit Module with 1 Output for externally-powered sounder control
55000-875 XP95 Mains Switch Input Output Module with 1 Supervised Input + 1 Relay x 220V
55000-832 XP95 Mini Switch monitor (interrupt) Mini input module (interrupt)
55000-833 XP95 mini switch monitor Mini Input module
59000-810 XPlorer Output Unit XPlorer Output Unit (Non-supervised)
59000-820 XPlorer Switch Monitor Supervised input module
Model Name Description
55000-803 XP95 DIN RAIL Input Output Unit DIN RAIL Module with 1Input + 1 Output
55000-804 XP95 DIN Rail Output Unit DIN Rail Module with 1 Output
55000-821 XP95 DIN RAIL Switch Monitor Plus DIN RAIL Module with 1 Delayed Input and Reset Output for
waterflow detectors (waterflow alarm)
55000-822 XP95 DIN RAIL Switch Monitor DIN RAIL Module with 1 Input
55000-812 XP95 DIN RAIL Zone Monitor (with Isolator) DIN RAIL Interface Module for Conventional Zones (with
isolator)
55000-826 XP95 DIN RAIL Sounder control Unit DIN RAIL Module with 1 sounder control output externally-
powered
55000-802 XP95 DIN RAIL Dual Isolator DIN RAIL Dual Isolator
Model Name Description
55000-841 XP95 Switch Monitor Plus with Isolator DIN RAIL module with 1 delayed input and reset output for waterflow
detectors (waterflow alarm)
55000-843 XP95 Switch Monitor with Isolator Single Input Module with Isolator
55000-845 XP95 Zone Monitor with Isolator Interface Module for Conventional Zones with Isolator
55000-847 XP95 Input/Output module with Isolator Module with 1relay output + 1 Supervised Input + 1 Non-supervised Input
(optoisolated)
55000-849 XP95 Output unit with isolator Module with 2 relay outputs with isolator
55000-852 XP95 Sounder control unit with isolator Module with 1output for self-powered siren (optoisolated)