EasyManua.ls Logo

innomar SES smart User Manual

Default Icon
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Innomar SES
Narrow-Beam Parametric Sub-Bottom Profilers
SES smart
SES compact
SES light / -plus
SES standard / -plus
SES medium-100
User’s Manual
SESWIN
SES NetViewer
SES Convert
2020-09
SES Model: S/N:

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the innomar SES smart and is the answer not in the manual?

innomar SES smart Specifications

General IconGeneral
Brandinnomar
ModelSES smart
CategoryMeasuring Instruments
LanguageEnglish

Summary

Important Hints and Safety Information

Safety Rules for Innomar SBP Systems

Essential safety guidelines for operating the Innomar SBP system.

What is Shipped with the System

Details the components included in the Innomar SBP delivery.

Hardware and System Installation Guide

System Overview

Provides a general description of the Innomar SBP system components.

Transducer Handling and Installation

Covers general guidelines for handling and installing the SBP transducer.

Topside Unit Installation Procedures

Instructions for correctly installing the SBP topside unit.

SBP Front Panel Connectors and Switches

Identifies and explains the connectors and controls on the SBP front panel.

Hull-Mount Transducer Installation

Specific instructions for installing hull-mounted transducers.

Ethernet and WiFi Setup for Smart/Compact Models

Network Connection Configuration

Guides users through setting up Ethernet and WiFi connections for system operation.

SES for Windows (SESWIN) System Software

Installing and Updating SESWIN Software

Instructions for installing or updating the SESWIN software.

Starting the SESWIN Software Application

Steps to launch and initiate the SESWIN application.

Understanding the SESWIN Screen Layout

Overview of the main SESWIN software interface elements.

Navigating SESWIN Menu Bars

Explains the different menu bars for system configuration and operation.

SESWIN Status Bar Interpretation

Details the information displayed in the SESWIN status bar.

SESWIN Home Menu Bar Settings

Covers survey-specific parameters like transmit, record, range, and gain settings.

SESWIN System Setup Configuration

Guide to configuring system parameters before a survey.

System Setup for Navigation Input (GNSS)

Configuration for integrating GNSS navigation data.

System Setup for Motion Sensor Input

Setup for motion sensor data for heave compensation.

SBP Synchronisation Modes and 1-PPS Input

Internal Synchronisation Setup

Configuring the system for internal trigger operation.

External Synchronisation Procedures

Setting up synchronization with external trigger devices.

Multi-Ping and Burst Mode Operation

Explanation of advanced ping modes for optimized ping rates.

1-PPS Input for Time Synchronization

Details the 1-PPS signal input for precise time synchronization.

Practical How-To Guides

Avoiding Engine Noise and Proper Transducer Mounting

Advice on minimizing engine noise and optimal transducer placement.

Setting Transducer Draught and Sound Velocity

Instructions for setting transducer depth and water sound velocity.

Setting Up Navigation Data Interface (SIS)

Configuring the system to receive and process navigation data.

Installing and Setting Up a Motion Sensor

Steps for installing and configuring motion sensors for data quality.

Avoiding Interference with Other Acoustic Systems

Strategies for preventing interference between acoustic systems.

Synchronizing with a Sparker at Fixed Ping Rate

Guide for synchronizing with a sparker system.

Using Broadcast Server with HYPACK®

How to stream data to HYPACK® survey software.

Resetting System to Factory Defaults

Procedure for resetting SESWIN system settings to default.

Maintenance and Error Handling Procedures

Hardware Handling and Maintenance Guidelines

Guidelines for handling and maintaining the system hardware.

SESWIN Error Messages at System Start

Explains common error messages during SESWIN software startup.

Troubleshooting No Incoming Sensor Data

Steps to troubleshoot issues with motion or position sensors.

Troubleshooting SESWIN Functions

Addresses common problems where SESWIN functions fail.

Resolving Signal Detection Problems

Solutions for issues like no seafloor echo or weak signals.

Firmware Update Procedure

Instructions for updating the system's firmware.

SES NetViewer Software Utility

SES NetViewer Overview and Usage

Introduction to the SES NetViewer tool for remote monitoring.

SES Convert Software for Data Conversion

Convert Innomar Data to SEG-Y using SESCONVERT

Step-by-step guide for converting data files using SESCONVERT.

SEG-Y Conversion and Processing Settings

Configuration options for SEG-Y data conversion and processing.

ISE Post-Processing Software Guide

Overview of ISE Software Capabilities

Introduction to the ISE software for data processing.

Data Acquisition and Post-Processing Workflow

Survey Preparation and Line Planning

Guidance on planning survey routes and preparing for data collection.

System Setup and Mobilisation Procedures

Procedures for setting up the system aboard the survey vessel.

Core Data Acquisition Process

Core process of collecting data with the SBP system.

Data Quality Check using ISE Software

Steps for ensuring data quality using the ISE software.

SEG-Y Data Export Instructions

Instructions for exporting data into SEG-Y format.

FAQ: Frequently Asked Questions

System Performance Issues and Solutions

Addresses common problems related to system performance and data display.

Trigger and Synchronization Configuration Questions

Frequently asked questions about trigger and synchronization settings.

Motion Sensor Compensation Queries

Answers to common queries regarding motion sensor usage and compensation.

Appendix A.1: Technical Specification SES smart

SES smart Main Technical Parameters

Key technical specifications for the SES smart model.

SES smart Hardware Specifications

Details on the topside unit and transducer hardware.

Appendix A.12: Data Acquisition and File Formats

Innomar SBP Data Formats Overview

Overview of SES, RAW, and SES3 data formats and their characteristics.

Appendix A.15: Operational Checklists

Checklist for System Setup and Survey Start

Checklist for preparing the system before starting a survey.

Checklist for Data Acquisition Settings

Guide to essential settings for optimal data acquisition.

Related product manuals