74 User’s Manual Innomar SES Parametric Sub-bottom Profilers
74 Innomar Technologie GmbH (2020-09)
4.14 SESWIN Network
The SESWIN network tools allow to transfer SBP data in real time to other data acquisition soft-
ware or to slave displays for quality check.
4.14.1 Network – Broadcast (RAW Data)
The broadcast server can be used to transmit echo print
data (either “SES” envelope data or “RAW” data) to
other computers for data observation using special soft-
ware (e.g. HYPACK
®
).
See also section 6.8 on page 104.
Local IP is given for information, has to be set in the client software used for data display.
Port has to be set according to network requirements.
Status gives the network status (connected / disconnected).
!
Please note that the envelope “SES” data format is obsolete.
Use the full-waveform “RAW” format instead.
!
This connection cannot be used for remote controlling the INNOMAR SBP system!
4.14.2 Network – Broadcast (Net Viewer)
If additional echo print screens are required for QC, data
of the SESWIN master channel is sent on a second port
by the broadcast server that may be received by
INNOMAR’s “SES NetView” application. See also section 8
on page 127.
Local IP is given for information, has to be set in the client software used for data display.
Port has to be set according to network requirements.
Status gives the network status (connected / disconnected).