-19-
AC800 Series Intelligent Machine Controller Hardware User Guide 4 Installation and Fixing
4 Installation and Fixing
4.1 Installation Requirements
4.1.1 Installation Environment
When installing the controller on the guide rail, take the operability, maintainability, and robustness into
account. Do not install the module in a location which is subject to
■ ambient temperature exceeding the range of -5 ℃ to 55 ℃
■ ambient humidity exceeding the range of 5% to 95%RH
■ drastic temperature change and condensation
■ corrosive and ammable gas
■ conductive powders such as dust and iron powder, oil mist, salt, and organic solvents
■ direct sunlight
■ strong electric and magnetic elds
■ vibration
4.1.2 Installation Space
To facilitate ventilation and module replacement, keep enough space between the module and its
surroundings.
Installation diagram
Rear earhook bracket installation Side earhook bracket installation
Figure 4 -1 Installation space for booksize controller
The clearances are shown in the following table:
Direction Min. dimension requirements (mm)
X 50
Y 100
Z 50