-49-
AC800 Series Intelligent Machine Controller Hardware User Guide 6 Operating Instructions
6.3.4 Page Switchover
When you switch pages on the display panel:
1) The screen will automatically turn o if there is no key operation for 15 minutes (the screen will not
turn o when there is an error window). When the screen is o, press any key to wake up the screen.
2) The programming interface page displays for 30 seconds before switching to the active page.
3) Apart from the programming interface page and error page, if you stay on a page for 2 minutes
without pressing any key, the screen will switch to the active page.
4) When you insert a USB drive and it is correctly recognized by the system, the display will directly switch
to the Settings menu, which is convenient for further operations. However, this does not apply to an
interactive page (a page related to upgrade, download, password input, and network port recovery).
6.4 System Upgrade
There are two ways to upgrade the PLC system
(1) InoProShop
You can connect to the PLC with the InoProShop tool and select the PLC rmware upgrade package and
accessory rmware upgrade package provided by the manufacturer to upgrade the PLC (see InoProShop
User Guide for details)
(2) USB drive
You can upgrade the PLC by inserting a USB ash drive on the PLC and carry out the upgrade procedure
on the display (see Setting (2) in section 6.3.3)