-45-
AC800 Series Intelligent Machine Controller Hardware User Guide 6 Operating Instructions
Requirements for download
a. The USB drive contains the application package named Application.userprg, which is packaged and
generated by InoProShop.
b. The package is in the root directory of the USB drive (if there are multiple packages, only the package in
the root directory is valid).
/PSNBM
"COPSNBM
%PXOMPBEJOH
%PXOMPBEJOH
3FTUBSUJOH
盛
"SFZPVTVSFZPV
XBOUUPEPXOMPBE
UIFQSPHSBN
&OUFS#BDL
%PXOMPBEGBJMFE
1) The program download is performed in an exclusive mode, that is, all key operations are
temporarily disabled until the download is successful or fails.
2) USB download and InoProShop tool download cannot be performed at the same time.
If you download the program through a USB drive rst, and then perform the download
again with the InoProShop tool, the tool will prompt "USB drive is updating rmware or
downloading application program". If you download the program through InoProShop
rst, and then perform the download again through the USB drive, the display will prompt
"Software tool is downloading program, please try again later".
(4) Program status at startup
You can use the Program Status at Startup menu to set the status of the application program at the next
PLC startup (the factory default is "1. Run program at startup").
Select this menu to enter the setting page. "<-" indicates the default startup status of the application
program set in the PLC. Use the Up and Down keys to select the status, and press the Enter key to conrm
the selection. After the setting is completed, "<-" will move to the selected item. If there are multiple
applications in the PLC, this operation will take eect for all of them.
Error handling
If any error occurs, the screen will show the error code in most cases. See section 3 Errors
for details. If the screen does not show the error code and does not repond to any key
operation, the PC may be freezing due to, for example, an innite loop in the application.
You can terminate and delete the application.
Steps
1. Press Back+Enter for 5s at the startup screen to set “Program status at startup” to “Stop”.
2. Reset the equipment through InoProShop (see Medium Size PLC Programming
Software User Guide) and download the correct application.
(5) Reset network ports A and B
You can use Reset Network Ports A and B to restore the network ports A and B to the default IP or dynamic
IP (as shown in the gure below). After the restoration is done, by setting the PC to the same network
segment as the PLC, you can connect to and operate the PLC through a cable (For example, you can
connect to port A by setting the PC to 192.168.1.X, and to port B by setting PC to 192.168.2.X).