EasyManua.ls Logo

Inovance CS500 - Main Circuit Terminals and Wiring

Inovance CS500
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.2.4 Main Circuit Terminals and Wiring
SafetyInformation
z Ensure that the power supply is cut off before wiring. Otherwise, electric shock may result.
z Wiring must be performed only by qualified personnel under instructions described in this
manual. Otherwise, equipment damage or personal injury may result.
z Ground the equipment reliably. Otherwise, electric shock or a fire may result.
Follow the instructions during wiring:
z Ensure that the input power is consistent with the rated value of the AC drive.
Otherwise, the AC drive may be damaged.
z Ensure that the motor is adaptable to the AC drive. Otherwise, motor damage or the
AC drive protection may result.
z Do not connect the power supply to the U, V, W terminals. Otherwise, the AC drive
may be damaged.
z Do not connect the braking resistor directly to the (+), (-) terminals of the DC bus.
Otherwise, a fire may result.
Terminal
Arrangement
CS500
Maximum Wiring
Size of the Power
Terminal
Torque of the
Torque Driver
CS500 mm
2
AWG kgf.cm
T0.7GB 2.5 14 10±0.5
T1.5GB 2.5 14 10±0.5
T2.2GB 2.5 14 10±0.5
CS500
Maximum Wiring Size of
the Power Terminal
Torque of the
Torque Driver
CS500 mm
2
AWG kgf.cm
T3.7GB 4.0 12 14±0.5
T5.5GB 4.0 12 14±0.5
efesotomas
y
on.com

Table of Contents

Related product manuals